Landfill Closure and Post-Closure Care
Hurst-Rosche Engineers, Inc. has assisted landfill owners and operators
with the design and permitting of landfill closure systems, developed
closure/post-closure care plans, and has provided quality assurance/quality
control for closure certification purposes.
Following is a listing of projects which Hurst-Rosche Engineers, Inc
has completed, including a brief description of each project, client
references for any particular project can be provided upon request. |
 |

Landfill closure diagram
|
 |
Roxana Landfill
Final Cover Design & Closure/Post-Closure Plan
Roxana, IL
Hurst-Rosche assisted in designing a composite final cover system for
this facility. The permitted final cover consists of a low
permeability layer, geomembrane liner, geocomposite drainage layer,
and protective cover soils. Numerous closure/post-closure care plans
have been prepared for this facility to address various closure and
post-closure care issues. |
|
 |
Chain of Rocks Recycling and Disposal Facility
Final Cover Certification
Granite City, IL
Hurst-Rosche has provided quality assurance/quality control services
for the incremental placement of final cover at this facility. Hurst-Rosche
also provided construction quality assurance/quality control services
for final closure of an older refuse disposal unit (approximately 40 acres)
at the site. Hurst-Rosche has also completed post-closure inspections
for the facility. |
|
 |
Milam Recycling and Disposal Facility
Final Cover Certification
Fairmont City, IL
Hurst-Rosche has provided quality assurance/quality control for final
cover placement at this facility. The final cover system consisted of a
two-foot thick clay barrier and 12-inch protective cover layer. The arial
extent of the construction was approximately 50 acres. |
|
 |
Greene County Landfill
Final Cover Certification
Greene County, IL
Hurst-Rosche provided project management and quality assurance/quality
control for final cover placement at this facility. The final cover system
consisted of a two-foot thick clay barrier layer and an 18-inch
protective cover layer. The aerial extent of the construction was
approximately 19 acres. |
|
 |
Litchfield-Hillsboro Landfill
Litchfield, IL
Hurst-Rosche provided quality assurance/quality control for final cover
placement at this facility. The final cover system consisted of a low
permeability barrier layer, geomembrane liner, and protective cover soil.
The extent of the construction was approximately 9 acres. |
|
 |
Alton Municipal Landfill
Final Closure
Alton, IL
Hurst-Rosche provided construction quality assurance/quality control
along with final certification for closure of this facility. Premature
closure of this facility required regrading of the site to promote
surface water runoff; the placement of a final cover system, which
consisted of a soil barrier layer, protective cover layer and a
vegetative cover; and appropriate field and laboratory testing to
verify that the work was completed in accordance with permit
conditions. |
|
 |
D & L Landfill
Final closure and closure/post-closure care
Greenville, IL
Hurst-Rosche has provided quality assurance/quality control for partial
and final closure of the existing landfill. The final cover system consisted
of a two-foot thick clay barrier layer overlain by a 12-inch thick
topsoil layer. The existing landfill encompasses approximately 32 acres.
Hurst-Rosche has prepared a closure/post-closure care plan for the
closed landfill and an adjacent 60 acre landfill facility. |
|
 |
Black Oak Recycling and Disposal Facility
Final Cover Certification
Hartville, MO
Hurst-Rosche has provided quality assurance/quality control services
for the placement of final cover over an approximate three acre area. The
final cover system consisted of a two-foot thick clay barrier layer and
a one-foot thick protective cover layer. Hurst-Rosche also documented
final cover placement over an older section of the landfill. |
|
 |
Cedar Hollow Recycling and Disposal Facility
Final Cover Certification
Owensville, MO
Hurst-Rosche provided quality assurance/quality control services for the
incremental placement of final cover at this facility. The areal extent
of the final cover operation was approximately three acres each.
|
|
 |
Ellis-Scott Sanitary Landfill
Cells A & B, Phase II
Clinton, Henry County, MO
Hurst-Rosche provided CQA services for interim cover of approximately 9
acres in Phase II. The interim cover consisted of a two ft. thick
soil liner and one ft. thick protective cover. |
|
 |
Jefferson City Landfill
Final Cover Certification
Jefferson City, MO
Hurst-Rosche provided certification for the incremental placement of
final cover at this facility. The area of final cover construction
encompasses an approximate 8 acre area.
|
 |
Inland Container Corporation Landfill
Final Cover Certification
Vermillion County, IN
Hurst-Rosche has provided certification for the incremental
placement of final cover at this facility.
|
 |
West Clinton Landfill
Final Cover Design and Closure/Post-Closure Plan
Vermillion County, IN
Hurst-Rosche designed and permitted a composite final cover system
for this facility. Hurst-Rosche also prepared a closure/post-closure
care plan for this facility.
|
 |
 |
 |
 |